2
Szűrési feltételek

Probe thermometer (HACCP)

Probe thermometer (HACCP)

Cikkszám:

Befejezetlen: 8 javaslat található.
    Mennyiség:

    Cikkszámlista

    Elemek száma

    Temperature measurement range (lower limit)

    (°C)

    Temperature measurement range (upper limit)

    (°C)

    Accuracy (+/-) °C

    (°C)

    Basic accuracy

    Basic accuracy

    (°C)

    Calibrated to

    Calibration service

    EN standard

    Power supply (details)

    Probe length

    (mm)

    Probe thermometer features

    Product size (height)

    (mm)

    Product size (depth)

    (mm)

    Product size (width)

    (mm)

    Product size (length)

    (mm)

    Resolution (temperature)

    (°C)

    Resolution

    (°C)

    Sample rate

    (s)

    Sensor type

    Temperature reading range

    Temperature range

    (°C)

    Weight

    (g)

    Sample rate

    Minimális rendelési mennyiség
    -50
    150
    1
    -
    ± 1
    Manufacturer's standards (no certificate)
    3 appropriate calibration values in the measuring range of the respective device (-20;0; +60 °C)
    EN 13485
    1 x LR44 batteries
    125
    Complies with HACCP standards
    26
    -
    24
    85
    0.1
    0.1
    -
    NTC|NTC
    -50 up to 150 °C
    -50 to +150
    36
    2 measurements per second
    1 darab
    -50
    350
    0.8
    ± 8
    -
    Manufacturer's standards (no certificate)
    3 appropriate calibration values in the measuring range of the respective device (-20;0; +60 °C)
    EN 13485
    CR 2032 button cell
    90
    Complies with HACCP standards
    20
    -
    42
    180
    0.1
    0.1
    5
    T|Type-F
    -50 up to 350 °C
    -50 to +350
    45
    -
    1 darab
    -30
    +200
    -
    -
    -
    Manufacturer's standards (with certificate)
    -
    EN 13485
    -
    -
    Complies with HACCP standards|IP65
    127
    -
    60
    16
    -
    -
    -
    -
    -30 up to +200 °C
    -
    90
    -
    1 darab
    -50
    400
    0.3
    -
    ±0.3
    Manufacturer's standards (no certificate)
    3 appropriate calibration values in the measuring range of the respective device (-20;0; +60 °C)
    EN 13485
    CR2477 lithium button cell 3 V/1 Ah
    130
    Complies with HACCP standards
    22
    -
    54
    109
    0.1
    0.1
    1
    Pt1000|Pt1000
    -50 up to 400 °C
    -50 to +400
    90
    -
    1 darab
    -50
    200
    0.3
    -
    -
    Manufacturer's standards (no certificate)
    -
    -
    -
    -
    Complies with HACCP standards
    22
    360
    54
    109
    0.1
    -
    -
    -
    -50 up to 200 °C
    -
    540
    -
    1 darab
    -25
    50
    0.3
    -
    -
    Manufacturer's standards (no certificate)
    -
    -
    -
    -
    -
    22
    360
    54
    109
    0.1
    -
    -
    Pt1000
    -25 up to 50 °C
    -
    540
    -
    1 darab
    -30
    220
    0.5
    -
    -
    ISO standards
    3 appropriate calibration values in the measuring range of the respective device (-18;0; +60 °C)
    EN 13485
    Button cell type CR2032
    -
    Complies with HACCP standards
    20
    -
    38
    116
    0.1
    -
    -
    NTC
    -30 up to 220 °C
    -30 to +220 °C
    41
    -
    1 darab
    -30
    +220
    0.5
    -
    -
    Manufacturer's standards (no certificate)
    -
    EN 13485
    Button cell type CR2032
    -
    Complies with HACCP standards
    20
    -
    38
    116
    0.1
    -
    -
    NTC
    -30 up to +220 °C
    -
    41
    -
    1 darab
    Egységár (HÉA nélkül)(egységár adóval)
    Normál feladási dátum
    54.20 €
    ( 64.50 € )
    3 munkanapok
    76.24 €
    ( 90.73 € )
    3 munkanapok
    114.37 €
    ( 136.10 € )
    3 munkanapok
    442.72 €
    ( 526.84 € )
    3 munkanapok
    622.00 €
    ( 740.18 € )
    3 munkanapok
    617.63 €
    ( 734.98 € )
    46 munkanapok
    183.96 €
    ( 218.91 € )
    9 munkanapok
    65.03 €
    ( 77.39 € )
    3 munkanapok