SMC
Filter Regulator AW20 to 60-B, Filter Regulator With Backflow Function AW20K to 60K-B
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter Regulator | NPT1/2 | 5 μm | – | 1 | Non-Relief / Relief | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Manual / Auto / Manual / Not Provided | None (Pressure Port Plug not available) / With Standard Pressure Gauge / With Pressure Switch |
SMC
Soft Start-Up Valve, AV2000 / 3000 / 4000 / 5000 Series
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Other FRL Combination Device | NPT1/2 | – | General Quality Dry Air | 1 | – | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | – | None (Pressure Port Plug not available) / With Standard Pressure Gauge |
SMC
AW10-40-A, AW Filter / Regulator Combination
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter Regulator | NPT1/2 | 5 μm | General Quality Dry Air | 1 | Non-Relief / Relief | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Manual / Auto / Manual / Not Provided | None (Pressure Port Plug not available) / With Standard Pressure Gauge |
SMC
3-Port Valve for Releasing Residual Pressure With Keyhole (Single Action) VHS20/30/40/50
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Other FRL Combination Device | NPT1/2 | – | General Quality Dry Air | 1 | – | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | – | – |
SMC
AC10-40-A (FRL), Modular Type, Air Filter + Regulator + Lubricator
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter + Regulator + Lubricator | NPT1/2 | 5 μm | General Quality Dry Air | 1 | Relief | Standard Flow (Left to Right) | Manual / Auto / Manual | None (Pressure Port Plug not available) / With Standard Pressure Gauge |
SMC
AV2000 / 3000 / 4000 / 5000-A, Soft Start-up Valve
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Other FRL Combination Device | NPT1/2 | – | General Quality Dry Air | 1 | – | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | – | None (Pressure Port Plug not available) / With Standard Pressure Gauge |
SMC
AC10A-40A-A (FRL), Modular Type, Filter Regulator + Lubricator
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter Regulator + Lubricator | NPT1/2 | 5 μm | General Quality Dry Air | 1 | Relief | Standard Flow (Left to Right) | Manual / Auto / Manual | None (Pressure Port Plug not available) / With Standard Pressure Gauge |
SMC
AC20A-B to AC60A-B, Modular Type, Filter Regulator + Lubricator
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter Regulator + Lubricator | NPT1/2 | 5 μm | General Quality Dry Air | 1 | Relief | Standard Flow (Left to Right) | Manual / Auto / Manual | No (With Pressure Port Plug) / With Standard Pressure Gauge |
SMC
AC10B-40B-A (FRL), Modular Type, Air Filter + Regulator
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter + Regulator | NPT1/2 | 5 μm | General Quality Dry Air | 1 | Relief | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Manual / Auto / Manual | None (Pressure Port Plug not available) / With Standard Pressure Gauge |
SMC
AC20B-B to AC60B-B, Modular Type, Air Filter + Regulator
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter + Regulator | NPT1/2 | 5 μm | General Quality Dry Air | 1 | Relief | Standard Flow (Left to Right) | Manual / Auto / Manual | No (With Pressure Port Plug) / With Standard Pressure Gauge |
SMC
AC Series Air Combination Piping Adapter
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Other FRL Combination Device | NPT1/2 | – | – | – | – | – | – | – |
CKD
Modular Type WL Combination Standard White Series
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter Regulator + Lubricator | NPT1/2 | 0.3µm / 5 μm | General Quality Dry Air | 1 | Non-Relief / Relief | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Manual / Auto | No (With Pressure Port Plug) / None (Pressure Port Plug not available) / With Standard Pressure Gauge |
SMC
Air Combination, Air Filter + Mist Separator + Regulator, AC20C-A to AC40C-A
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter + Mist Filter + Regulator | NPT1/2 | 5 μm | General Quality Dry Air | 1 | Relief | Standard Flow (Left to Right) | Manual / Auto / Manual / Not Provided | None (Pressure Port Plug not available) / With Standard Pressure Gauge |
SMC
Mist Separator Regulator AWM20 to 40/Micro Mist Separator Regulator AWD20 to 40
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter Regulator | NPT1/2 | 0.3µm / 0.01µm | – | 1 | Non-Relief / Relief | Standard Flow (Left to Right) | Manual / Auto / Manual | None (Pressure Port Plug not available) / With Standard Pressure Gauge |
SMC
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Other FRL Combination Device | NPT1/2 | – | General Quality Dry Air | 1 | – | Standard Flow (Left to Right) | – | – |
SMC
AC20-B to AC60-B, Modular Type, Air Filter + Regulator + Lubricator
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter + Regulator + Lubricator | NPT1/2 | 5 μm | General Quality Dry Air | 1 | Relief | Standard Flow (Left to Right) | Manual / Auto / Manual | No (With Pressure Port Plug) / With Standard Pressure Gauge |
SMC
AC20C-B to AC40C-B, Modular Type, Air Filter + Mist Separator + Regulator
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter + Mist Filter + Regulator | NPT1/2 | 5 μm | General Quality Dry Air | 1 | Relief | Standard Flow (Left to Right) | Manual / Auto / Manual | With Standard Pressure Gauge |
SMC
AC20D-B to AC40D-B, Modular Type, Filter Regulator + Mist Separator
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter Regulator + Mist Filter | NPT1/2 | 5 μm | General Quality Dry Air | 1 | Relief | Standard Flow (Left to Right) | Manual / Auto / Manual | No (With Pressure Port Plug) / With Standard Pressure Gauge |
CKD
Modular Type FM Combination Standard White Series
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter + Mist Filter | NPT1/2 | 0.3µm / 5 μm | General Quality Dry Air | 1 | – | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Manual / Auto | – |
CKD
Modular Type FRL Combination Standard White Series
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter + Regulator + Lubricator | NPT1/2 | 0.3µm / 5 μm | General Quality Dry Air | 1 | Non-Relief / Relief | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Manual / Auto | No (With Pressure Port Plug) / None (Pressure Port Plug not available) |
CKD
Modular Type WM Combination Standard White Series
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter Regulator + Mist Filter | NPT1/2 | 0.3µm / 5 μm | General Quality Dry Air | 1 | Non-Relief / Relief | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Manual / Auto | No (With Pressure Port Plug) / None (Pressure Port Plug not available) / With Pressure Switch / With Pressure Sensor |
CKD
Modular type filter and regulator standard white series
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter Regulator | NPT1/2 | 0.3µm / 5 μm | General Quality Dry Air | 1 | Non-Relief / Relief | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Manual / Auto / Auto / Manual | No (With Pressure Port Plug) / None (Pressure Port Plug not available) / With Pressure Switch / With Pressure Sensor |
CKD
Modular Reverse Filter Regulator Standard White Series
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter Regulator | NPT1/2 | 0.3µm / 5 μm | General Quality Dry Air | 1 | Non-Relief / Relief | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Manual / Auto | No (With Pressure Port Plug) / None (Pressure Port Plug not available) / With Standard Pressure Gauge / With Pressure Switch / With Pressure Sensor |
SMC
AC20D-40D-A (FRL), Modular Type, Filter Regulator + Mist Separator
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter Regulator + Mist Filter | NPT1/2 | 5 μm | General Quality Dry Air | 1 | Relief | Standard Flow (Left to Right) | Manual / Auto / Manual | None (Pressure Port Plug not available) / With Standard Pressure Gauge |
CKD
FFM Combination (Standard Modular Type) C * 070 Series
Regulator Unit Combination | Connection Diameter | Filter, Filtration Level | Compressed Air Quality | Max. Working Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter + Mist Filter + Micro Mist Filter | NPT1/2 | – | General Quality Dry Air | 1 | – | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Manual / Auto | – |