Individual wiring manifold M3GB1· 2 / M4GB1-3R-(D) series single unit

Individual wiring manifold M3GB1· 2 / M4GB1-3R-(D) series single unit
The new M3GB1/2/M4GB1 to 3R-(D) series have inherited the legacy 3G/4G series concept and evolved it further.

[Environmental Performance]
· Continuous power OK (single solenoid type). Uses a new coil actuator.
· Reduced power consumption.
[Safety]
· Manual misoperation prevention (manual device has a protective cover).
· Suppresses malfunctioning problems (metal base, exhaust malfunction prevention valve regardless of resin block come as standard).
· Foreign matter problem prevention
[Reliability]
· Low sliding · Realizes long life
· Improved leave response
[Ease of use]
· Wiring connector horizontal sharing
· Uses rotary connector

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

Part Number
4GB129R-00-7
4GB129R-00-[E00,​E01J,​E01,​E02J,​E02,​E03J,​E03,​E0N,​E0,​E1,​E2N,​E2,​E3,​E20,​E21J,​E21,​E22J,​E22,​E23J,​E23]-7
4GB149R-00-7
4GB149R-00-[E00,​E01J,​E01,​E02J,​E02,​E03J,​E03,​E0N,​E0,​E1,​E2N,​E2,​E3,​E20,​E21J,​E21,​E22J,​E22,​E23J,​E23]-7
4GB219R-00-7
4GB219R-00-[B,​BN,​E00,​E01J,​E01,​E02J,​E02,​E03J,​E03,​E0N,​E0,​E1,​E2N,​E2,​E3,​E20,​E21J,​E21,​E22J,​E22,​E23J,​E23]-7
4GB239R-00-7
4GB239R-00-[B,​BN,​E00,​E01J,​E01,​E02J,​E02,​E03J,​E03,​E0N,​E0,​E1,​E2N,​E2,​E3,​E20,​E21J,​E21,​E22J,​E22,​E23J,​E23]-7
4GB319R-00-7
4GB319R-00-[B,​BN,​E00,​E01J,​E01,​E02J,​E02,​E03J,​E03,​E0N,​E0,​E1,​E2N,​E2,​E3,​E20,​E21J,​E21,​E22J,​E22,​E23J,​E23]-7
Part NumberMinimum order quantityVolume Discount
Standard
Shipping Days
?
Number of Solenoids Switching Type Status at Power Off Voltage Compatible Cylinder Diameter
(Ø)
Connection Diameter Electrical Wiring Connection
1 14 Days Double2-position exhaustSelf-Holding12 V DC / 24 V DC / 100 V AC / 5 V DC / 3 V DC20–40For single valve unit to be equipped to the baseGrommet Lead Wire
1 14 Days Double2-position exhaustSelf-Holding12 V DC / 24 V DC / 100 V AC / 5 V DC / 3 V DC20–40For single valve unit to be equipped to the baseE0 / E00 / E0N / E1 / E01 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J
1 14 Days Double3 Position A · B · R Connection[Self-Reset (Spring Return)] Self-Reset (Spring Return)12 V DC / 24 V DC / 100 V AC / 5 V DC / 3 V DC20–40For single valve unit to be equipped to the baseGrommet Lead Wire
1 14 Days Double3 Position A · B · R Connection[Self-Reset (Spring Return)] Self-Reset (Spring Return)12 V DC / 24 V DC / 100 V AC / 5 V DC / 3 V DC20–40For single valve unit to be equipped to the baseE0 / E00 / E0N / E1 / E01 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J
1 14 Days Single2-position exhaustSelf-reset(differential pressure return)12 V DC / 24 V DC / 100 V AC / 200 V AC / 5 V DC / 3 V DC40 to 80For single valve unit to be equipped to the baseGrommet Lead Wire
1 14 Days Single2-position exhaustSelf-reset(differential pressure return)12 V DC / 24 V DC / 100 V AC / 200 V AC / 5 V DC / 3 V DC40 to 80For single valve unit to be equipped to the baseE0 / E00 / E0N / E1 / E01 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J / B / BN
1 14 Days Double[3-Position Closed Center] 3 Position All Ports Blocked[Self-Reset (Spring Return)] Self-Reset (Spring Return)12 V DC / 24 V DC / 100 V AC / 200 V AC / 5 V DC / 3 V DC40 to 80For single valve unit to be equipped to the baseGrommet Lead Wire
1 14 Days Double[3-Position Closed Center] 3 Position All Ports Blocked[Self-Reset (Spring Return)] Self-Reset (Spring Return)12 V DC / 24 V DC / 100 V AC / 200 V AC / 5 V DC / 3 V DC40 to 80For single valve unit to be equipped to the baseE0 / E00 / E0N / E1 / E01 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J / B / BN
1 14 Days Single2-position exhaustSelf-reset(differential pressure return)12 V DC / 24 V DC / 100 V AC / 200 V AC / 5 V DC / 3 V DC63 to 100For single valve unit to be equipped to the baseGrommet Lead Wire
1 14 Days Single2-position exhaustSelf-reset(differential pressure return)12 V DC / 24 V DC / 100 V AC / 200 V AC / 5 V DC / 3 V DC63 to 100For single valve unit to be equipped to the baseE0 / E00 / E0N / E1 / E01 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J / B / BN

Loading...

  1. 1

Basic information

Type Electromagnetic Valve Application Unit for manifold Number of Ports 5-port valve
Installation method Manifold Base Features Standard / Oil-Free Pipe Port Type No port specified
Plumbing Subbase Plumbing Driving Type Pilot-operated Spool Seal Type Soft seal

Tech Support

Technical Support
Tel:+49 69 668173-0 / FAX:+49 69 668173-360