Regulators / In-Line with Gauge (Part Numbers - CAD Download)

Regulators / In-Line with Gauge

Click on this image to zoom in.

Click on this image to zoom in.

  • Volume Discount
A regulator equipped with a pressure gauge for checking the pressure.

*When using with a soft tube, such as one made from urethane, use a tube ferrule insert to prevent the tube coming out.

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

RGUNP6

Regulators/In-Line with Gauge:Related Image

Specifications

Part Number
RGUNP4
Part NumberD1D2BL1L2L3L4P1P2P3C1C2E1E2F1F2F3F4F5F6F7F8T1T2X1X2Y1Y2Mass (g)Unit PriceVolume Discount Rate
TypeNo.MaxMin1 ~ 9 pc(s).10~30
RGUNP44461.65943.31318.8111.511.515111121.630.615304.21710.120.210.2924.5159.89.87.87.823  
6-4611.62211.89.89.8  
6611.63111.89.8  
8-6865.763.149.81522.5-15.515.51918.11728.63319.939.74.121.311.623.29.11328.419----36  
8818.132.9  
For orders larger than indicated quantity, please check with WOS.

Part Number:  

    3D preview is not available, because the part number has not yet been determined.

  • In order to open the 3D preview, the part number must be fixed.
Loading...
Part Number
RGUNP6
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Connection Dia. on Supply Side (D1)
(mm)
Connection Dia. on Control Side (D2)
(mm)

42.57 €

1 Available 5 Days 66

Loading...

  1. 1

More Information

■Precautions for Use
Do not use the regulator in such a way that the pressure exceeds the preset level due to large pressure fluctuations on the secondary side.
This product is not designed as a relief valve, and using it as one may cause equipment damage or malfunction.
If using it in this way, please install additional safety mechanisms.
■Precautions for Use
1. Set the pressure by turning the regulating knob in the upward direction (clockwise). The pressure cannot be set accurately if the regulating knob is turned in the downward direction (counterclockwise).
2. Do not turn the regulating knob counterclockwise from a fully open position, or too far clockwise from a fully open position.
Doing so may cause damage to the regulating knob or the regulator/valve itself. It can also increase the torque on the regulating screw and regulating knob.
3. The regulating knob releases when pulled up and locks when pushed down. Always lock the knob after adjusting the pressure. Failure to lock the regulating knob means the knob may turn, causing the pressure to change.
4. When you press down the regulating knob, it can sometimes stop partway between the locked and unlocked positions depending on how far round it is rotated. When this happens, the knob is not completely locked. Please ensure that the regulating knob is fully pushed down to the locked position.
5. Trying to force the regulating knob to turn while it is in the locked position may cause damage to the locking mechanism.
6. For models with a gauge, the gauge can be oriented in any direction. Applying excessive force to the gauge cap can result in damage to the gauge and cause issues with gauge readings. Please hold the gauge close to the base when turning it.
7. The pressure gauge is accurate to ±5% (FS). If greater accuracy is required, please check the pressure using a separate pressure gauge and adjust accordingly.
8. When air is released from the secondary side, the air flow may cause resonance. Avoid releasing air on the secondary side for prolonged periods of time, as this poses a risk of internal damage or other issues.
■Pressure Adjustment Method
1. Adjusting the pressure
Release the lock by pulling the regulating knob upward before adjusting the pressure. Do not apply excessive force to the regulating knob during this time, as doing so may cause damage.
Regulators/In-Line with Gauge:Related Image
2. Increasing the pressure
Turn the regulating knob clockwise from the fully open position to increase the pressure. When the desired pressure is reached, be sure to push the regulating knob down to lock it in place so that the pressure setting does not change.
3. Decreasing the pressure
If the regulator knob is turned too far (if the pressure is too high), turning it counterclockwise will activate the relief mechanism and decrease the pressure. Following this, adjust as described in "2. Increasing the pressure." When the desired pressure is reached, be sure to push the regulating knob down to lock it in place so that the pressure setting does not change.
Regulators/In-Line with Gauge:Related Image
Specifications
Applicable FluidAir
Operating Temp. Range0 ~ 60°C
Operating Pressure Range0~1MPa
Set Pressure Range0.1~0.8MPa
(Indicated Pressure Range)0~0.8MPa
Gauge Accuracy±5% (Full Scale *)
*Displayed position differences when the displayed pressure has suddenly changed from 0 to Max. value of 0.8MPa.

Basic information

Type Speed Controllers Joint Type Both Sides One-Touch Fitting Usage Environment/Application Standard
Operating Temperature Range(℃) 0::60 Operating Pressure Range(MPa) 0::0.9

This page is Regulators / In-Line with Gauge, part number RGUNP6.
You can find the detail information about specifications and dimensions on part number RGUNP6.

Variation of this product

Part Number
RGUNP4
RGUNP6-4
RGUNP8
RGUNP8-6
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountStandard
Shipping Days
?
Connection Dia. on Supply Side (D1)
(mm)
Connection Dia. on Control Side (D2)
(mm)

40.66 €

1 Available 5 Days 44

38.13 €

1 Available 5 Days 64

43.83 €

1 Available 5 Days 88

43.06 €

1 Available 5 Days 86

Complementary Products

MISUMI Unit еxample related to this product

Tech Support

Technical Support
Tel:+49 69 668173-0 / FAX:+49 69 668173-360