Non-separating guards
According to the Machinery Directive, any device without a separating function is considered a non-separating protective device, which either reduces the risk on its own or, in conjunction with a separating protective device, ensures that persons do not gain access to the hazardous area of a machine or system.
Non-separating safeguards are divided into:
• Non-contact protective devices (BWS)
• Contact-actuated or pressure-sensitive protective devices
• Protective devices with location dependency
The non-contact protective device uses sensors to detect when a person or body part enters the defined protective area. This does not require direct mechanical contact. Their mode of action is based on different physical principles. Acoustically, for example via ultrasound, it is determined whether people are moving in the hazardous area. The optical principle uses light curtains, digital cameras, etc. Inductive proximity switches are suitable for electrically conductive objects and a capacitive spacer sensor is recommended at relatively short distances.
All non-contact protective devices have in common that they consist of a sensor, a control or monitoring function and output switching elements. These elements cause the safety function to trigger when the control or monitoring function responds. Requirements for non-contact protective devices are specified in DIN EN IEC 61496-1. If you would like to learn more about sensors and their importance in automation technology, please also read our article Sensor technology - selection and importance for automation technology.
Pressure-sensitive or contact-actuated protective devices trigger the safety function due to elastic deformation. This is realized, for example, by means of switch mats or switch strips. When a person steps onto the mat, internal signal transmitters detect deformation in a hollow body, resulting in tripping. It should be noted that the corresponding standards only include persons from a body weight of 20 kg upward.
Location-dependent protective devices must in most cases be installed outside the hazardous area. This type of protective device is triggered by hand or foot, e.g. two-hand pushbuttons, foot switches or two-hand controls. The operator is also outside the hazardous area due to the positioning of the protective device. In the case of two-hand switching, the hazardous function is only triggered, for example, if the operator initiates it by actuating two control devices. At this point, however, it is important to note that a two-hand control only protects one person. If several people are working on a machine, a two-hand function must also be set up for each of these people. The following principles apply to two-hand controls:
• Both hands are used.
• When a control unit is released, the hazardous function also stops.
• Accidental actuation and bypassing are excluded.
• The two-hand control is permanently out of the hazardous area.